Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 125
Filtrar
1.
Eur J Radiol ; 175: 111467, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38636410

RESUMO

PURPOSE: To describe the reliability of ultra-high-resolution computed tomography (UHR-CT) in the measurement of titanium stapes prostheses using manufacturer data as a reference. MATERIALS AND METHODS: This retrospective study included patients treated by stapedectomy with titanium prostheses who underwent UHR-CT between January 2020 and October 2023. Images were acquired using an ultra-high-resolution mode (slice thickness: 0.25 mm; matrix, 1024 × 1024). Two radiologists independently evaluated the length, diameter, and intra-vestibular protrusion of the prosthesis. Post-operative air-bone gaps (ABGs) were recorded. RESULTS: Fourteen patients were enrolled (mean age, 44.3 ± 13.8 [SD] years, 9 females), resulting in 16 temporal bone UHR-CTs. The exact length was obtained in 81.3 % (n = 13/16) and underestimated by 0.1 to 0.3 mm in the remaining 18.7 % (n = 3/16) CT scans for both readers (mean misestimation: -0.02 ± 0.06 [SD] mm, overall underestimation of 0.43 %). The exact diameter was reported in 75 % (n = 12/16) and 87.5 % (n = 14/16) of the CT scans for readers 1 and 2, respectively, and was off by 0.1 mm in all discrepancies (mean misestimation: 0.01 ± 0.04 [SD] mm, overall overestimation of 2.43 %). Intravestibular prosthesis protrusion was of 0.5 ± 0.43 [SD] mm (range: 0-1) and 0.49 ± 0.44 [SD] mm (range: 0-1.1) for readers 1 and 2, respectively, and did not correlate with ABGs (r = 0.25 and 0.22; P = 0.39 and 0.47 for readers 1 and 2, respectively). Intra and interobserver agreements were excellent. CONCLUSION: UHR-CT provides 99.6 % and 97.6 % accuracy for prosthesis length and diameter measurements, respectively.

2.
Eur J Radiol ; 173: 111394, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38428256

RESUMO

INTRODUCTION: Strategies for achieving high resolution varies between manufacturers. In CT, the helical mode with narrow collimation has long been considered as the gold standard for high-resolution imaging. More recently, incremental modes with small dexels and focal spot, have been developed but have not been compared with helical acquisitions under optimal conditions. The aim of this work is to compare the high-resolution acquisition strategies currently proposed by recent MSCT. METHODS: Three CT systems were compared. A phantom was used to evaluate geometric accuracy, uniformity, scan slice geometry, and spatial resolution. Human dry bones were used to test different protocols on real bone architecture. A blind visual analysis was conducted by trained CT users for classifying the different acquisitions (p-values). RESULTS: All systems give satisfactory results in terms of geometric accuracy and uniformity. The in-plane MTF at 5% were respectively 13.4, 15.9 and 18.1 lp/cm. Dry-bones evaluation confirms that acquisition#3 is considered as the best. CONCLUSIONS: The incremental acquisition coupled with à small focal spot, and a high-sampling detector, overpasses the reference of low-pitch helical acquisitions for high-resolution imaging. Cortical bone, bony vessels, and tumoral matrix analysis are the very next challenges that will have to be managed to improve normal and pathologic bone imaging thanks to the availability UHR-CT systems.


Assuntos
Osso e Ossos , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Osso e Ossos/diagnóstico por imagem
3.
Cancers (Basel) ; 16(5)2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38473238

RESUMO

Background: RT-induced hyalinization/fibrosis was recently evidenced as a significant independent predictor for complete response to neoadjuvant radiotherapy (RT) and survival in patients with soft tissue sarcoma (STS). Purpose: Non-invasive predictive markers of histologic response after neoadjuvant RT of STS are expected. Materials and Methods: From May 2010 to April 2017, patients with a diagnosis of STS who underwent neoadjuvant RT for limb STS were retrieved from a single center prospective clinical imaging database. Tumor Apparent Diffusion Coefficients (ADC) and areas under the time-intensity perfusion curve (AUC) were compared with the histologic necrosis ratio, fibrosis, and cellularity in post-surgical specimens. Results: We retrieved 29 patients. The median ADC value was 134.3 × 10-3 mm2/s. ADC values positively correlated with the post-treatment tumor necrosis ratio (p = 0.013). Median ADC values were lower in patients with less than 50% necrosis and higher in those with more than 50% (120.3 × 10-3 mm2/s and 202.0 × 10-3 mm2/s, respectively (p = 0.020). ADC values higher than 161 × 10-3 mm2/s presented a 95% sensitivity and a 55% specificity for the identification of tumors with more than 50% tumor necrosis ratio. Tumor-to-muscle AUC ratios were associated with histologic fibrosis (p = 0.036). Conclusions: ADC and perfusion AUC correlated, respectively, with radiation-induced tumor necrosis and fibrosis.

4.
Diagn Interv Imaging ; 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38368178

RESUMO

PURPOSE: The purpose of this study was to evaluate the ability of ultra-high-resolution computed tomography (UHR-CT) to assess stapes and chorda tympani nerve anatomy using a deep learning (DLR), a model-based, and a hybrid iterative reconstruction algorithm compared to simulated conventional CT. MATERIALS AND METHODS: CT acquisitions were performed with a Mercury 4.0 phantom. Images were acquired with a 1024 × 1024 matrix and a 0.25 mm slice thickness and reconstructed using DLR, model-based, and hybrid iterative reconstruction algorithms. To simulate conventional CT, images were also reconstructed with a 512 × 512 matrix and a 0.5 mm slice thickness. Spatial resolution, noise power spectrum, and objective high-contrast detectability were compared. Three radiologists evaluated the clinical acceptability of these algorithms by assessing the thickness and image quality of the stapes footplate and superstructure elements, as well as the image quality of the chorda tympani nerve bony and tympanic segments using a 5-point confidence scale on 13 temporal bone CT examinations reconstructed with the four algorithms. RESULTS: UHR-CT provided higher spatial resolution than simulated conventional CT at the penalty of higher noise. DLR and model-based iterative reconstruction provided better noise reduction than hybrid iterative reconstruction, and DLR had the highest detectability index, regardless of the dose level. All stapedial structure thicknesses were thinner using UHR-CT by comparison with conventional simulated CT (P < 0.009). DLR showed the best visualization scores compared to the other reconstruction algorithms (P < 0.032). CONCLUSION: UHR-CT with DLR results in less noise than UHR-CT with hybrid iterative reconstruction and significantly improves stapes and tympanic chorda tympani nerve depiction compared to simulated conventional CT and UHR-CT with iterative reconstruction.

5.
Eur Radiol ; 2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-38206402

RESUMO

OBJECTIVE(S): To determine the frequency of olfactory cleft (OC) stenosis and obstruction on paranasal sinus CT scans in pre-septorhinoplasty of patients who had septal deviation, septopyramidal deformation or nasal obstruction without other sinonasal conditions. METHODS: This retrospective study included patients referred to our institution between December 2013 and December 2021 for septorhinoplasty due to nasal obstruction without other sinonasal or neurological conditions. All patients underwent preoperative paranasal sinus CT scan and olfactory testing. OC stenosis was quoted as none, partial, or total (less than 1/3 contact between nasal septum and ethmoid turbinates, 1/3-2/3, more than 2/3, respectively), as well as OC obstruction as none, partial, or complete (obstruction of less than 1/3 of OC, 1/3-2/3, more than 2/3, respectively). Radiologic evaluation was validated by near perfect interobserver agreement. RESULTS: A total of 75 patients (32 women, 43 men) with a mean age of 44.2 ± 15.64 (23-74) years were included, of which 36 were normosmic and 39 hyposmic. OC stenosis was partial in 58.7% (n = 44) of the patients, absent in 28% (n = 21), and total in 13.3% (n = 10), without difference between normosmic and hyposmic patients (p = .66). OC obstruction was absent in 52% (n = 39) and partial in 46.7% (n = 35), without difference between normosmic and hyposmic patients (p = .51). Only one normosmic patient had complete OC obstruction. CONCLUSION: OC partial stenosis and partial obstruction were frequent findings in pre-septorhinoplasty patients without respiratory mucosa disease and did not influence their olfactory status. Total stenosis and complete obstruction were rarer and require further investigation. CLINICAL RELEVANCE STATEMENT: Isolated partial olfactory cleft stenosis and obstruction should be considered normal variants, whereas the impact of complete olfactory cleft stenosis and obstruction on patient's olfactory status remains to be determined. KEY POINTS: • The incidence of olfactory cleft stenosis and obstruction in asymptomatic patients remains unknown, even though it is encountered in clinical practice. • Partial and total olfactory cleft stenosis occurred in 58.7% and 13.3% of the patients; partial obstruction occurred in half of the cases, but complete obstruction was extremely rare. • There are frequent findings of partial olfactory cleft obstruction and stenosis, but complete obstruction and total stenosis should be further investigated.

6.
Diagn Interv Imaging ; 105(1): 26-32, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37482455

RESUMO

PURPOSE: The purpose of this study was to evaluate the ability to depict in vivo bone vascularization using ultra-high-resolution (UHR) computed tomography (CT) with deep learning reconstruction (DLR) and hybrid iterative reconstruction algorithm, compared to simulated conventional CT, using osteoid osteoma as a model. MATERIALS AND METHODS: Patients with histopathologically proven cortical osteoid osteoma who underwent UHR-CT between October 2019 and October 2022 were retrospectively included. Images were acquired with a 1024 × 1024 matrix and reconstructed with DLR and hybrid iterative reconstruction algorithm. To simulate conventional CT, images with a 512 × 512 matrix were also reconstructed. Two radiologists (R1, R2) independently evaluated the number of blood vessels entering the nidus and crossing the bone cortex, as well as vessel identification and image quality with a 5-point scale. Standard deviation (SD) of attenuation in the adjacent muscle and that of air were used as image noise and recorded. RESULTS: Thirteen patients with 13 osteoid osteomas were included. There were 11 men and two women with a mean age of 21.8 ± 9.1 (SD) years. For both readers, UHR-CT with DLR depicted more nidus vessels (11.5 ± 4.3 [SD] (R1) and 11.9 ± 4.6 [SD] (R2)) and cortical vessels (4 ± 3.8 [SD] and 4.3 ± 4.1 [SD], respectively) than UHR-CT with hybrid iterative reconstruction (10.5 ± 4.3 [SD] and 10.4 ± 4.6 [SD], and 4.1 ± 3.8 [SD] and 4.3 ± 3.8 [SD], respectively) and simulated conventional CT (5.3 ± 2.2 [SD] and 6.4 ± 2.5 [SD], 2 ± 1.2 [SD] and 2.4 ± 1.6 [SD], respectively) (P < 0.05). UHR-CT with DLR provided less image noise than simulated conventional CT and UHR-CT with hybrid iterative reconstruction (P < 0.05). UHR-CT with DLR received the greatest score and simulated conventional CT the lowest score for vessel identification and image quality. CONCLUSION: UHR-CT with DLR shows less noise than UHR-CT with hybrid iterative reconstruction and significantly improves cortical bone vascularization depiction compared to simulated conventional CT.


Assuntos
Neoplasias Ósseas , Aprendizado Profundo , Osteoma Osteoide , Masculino , Humanos , Feminino , Criança , Adolescente , Adulto Jovem , Adulto , Osteoma Osteoide/diagnóstico por imagem , Osteoma Osteoide/cirurgia , Estudos Retrospectivos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Osso Cortical/diagnóstico por imagem , Algoritmos , Neoplasias Ósseas/diagnóstico por imagem
7.
Eur Radiol ; 34(1): 686-691, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37566269

RESUMO

OBJECTIVES: Evaluate the prevalence of radiological anomalies on orthopantomograms (OPT) performed as part of forensic age estimation in unaccompanied minors. METHODS: This is a retrospective study conducted on 208 OPT examinations requested by a magistrate. These OPTs were interpreted independently by two readers to establish the number of missing teeth (MT), presence of dental fillings (DF), and dental anomalies (DA). The presence of radiolucent (RL), radiopaque, and mixed lesions was also assessed. RESULTS: Most radiologic anomalies were RL, detected on 41% and 39% of the subjects evaluated for R1 and R2, respectively, with a mean of 1.3 ± 2.4 (1-16) and 1.1 ± 2 (1-13) RL lesions per subject. Among the RL identified, the majority were dental (70% for R1 and 65% for R2), all of which had a suspected infectious origin. Among readers, 43% and 41% of the subjects evaluated presented MT, 21% and 15% presented DF, and 22% and 20% presented DA for R1 and R2, respectively. The inter- and intra-observer reproducibility for OPT classification was considered excellent (Kappa = 0.84, 95% CI 0.78-0.90, and Kappa = 0, 95, 95% CI 0.86-0.99). DISCUSSION: There was a non-negligible prevalence of radiological anomalies in OPT studies performed for forensic age estimation. Most of these lesions were suspected to be infectious in origin, potentially requiring medical care. This constitutes an ethical dilemma inherent in the judicial expertise injunction requiring a limited specific response. CLINICAL RELEVANCE STATEMENT: This study highlights a non-negligible prevalence of supposedly infectious radiological abnormalities. The restricted possibility for the legal expert to declare these abnormalities raises ethical and medical questions. KEY POINTS: • Orthopantomograms can be performed as part of forensic age estimation. • Results indicate the majority of radiological anomalies detected on OPTs were of suspected infectious origin. • These findings give rise to ethical and medical questions about the way in which these forensic examinations are carried out.


Assuntos
Determinação da Idade pelos Dentes , Refugiados , Humanos , Determinação da Idade pelos Dentes/métodos , Prevalência , Reprodutibilidade dos Testes , Estudos Retrospectivos , Radiografia Panorâmica , Odontologia Legal
8.
Forensic Sci Int ; 354: 111903, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38096752

RESUMO

INTRODUCTION: The morphological assessment of the pubic symphysis using the Suchey-Brooks method is considered a reliable age at death indicator. Age at death estimation methods can be adapted to the images obtained from post-mortem computed tomography (PMCT). The aim of this study is to evaluate the utility of pubic symphysis photorealistic images obtained through Global illumination rendering (GIR) for age at death estimation from whole-body PMCT and from focused PMCT on the pubic bone. MATERIALS AND METHODS: We performed virtual age at death estimation using the Suchey Brooks method from both the whole-body field of view (Large Field of View: LFOV) and the pubis-focused field of view (Small and Field of View: SFOV) of 100 PMCT. The 3D photorealistic images were evaluated by three forensic anthropologists and the results were statistically evaluated for accuracy of the two applied PMCT methods and the intra- and inter-observer errors. RESULTS: When comparing the two acquisitions of PMCT, the accuracy rate reaches 98.5% when using a pubic-focused window (SFOV) compared to 86% with a whole-body window (LFOV). Additionally, the intra- and inter-observer variability has demonstrated that the focused window provides better repeatability and reproducibility. CONCLUSION: Adding a pubic-focused field of view to standard PMCT and processing it with GIR appears to be an applicable technique that increases the accuracy rate for age at death estimation from the pubic symphysis.


Assuntos
Sínfise Pubiana , Humanos , Sínfise Pubiana/diagnóstico por imagem , Sínfise Pubiana/anatomia & histologia , 60692 , Reprodutibilidade dos Testes , Determinação da Idade pelo Esqueleto/métodos , Imageamento Tridimensional , Antropologia Forense
9.
Semin Musculoskelet Radiol ; 27(4): 397-410, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37748463

RESUMO

Bone microarchitecture has several clinical implications over and above estimating bone strength. Computed tomography (CT) analysis mainly uses high-resolution peripheral quantitative CT and micro-CT, research imaging techniques, most often limited to peripheral skeleton assessment. Ultra-high-resolution (UHR) CT and photon-counting detector CT, two commercially available techniques, provide images that can approach the spatial resolution of the trabeculae, bringing bone microarchitecture analysis into clinical practice and improving depiction of bone vascularization, tumor matrix, and cortical and periosteal bone. This review presents bone microarchitecture anatomy, principles of analysis, reference measurements, and an update on the performance and potential clinical applications of these new CT techniques. We also share our clinical experience and technical considerations using an UHR-CT device.


Assuntos
Osso Esponjoso , Tomografia Computadorizada por Raios X , Humanos , Compostos Radiofarmacêuticos
10.
Semin Musculoskelet Radiol ; 27(4): 471-479, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37748471

RESUMO

Focal bone lesions are frequent, and management greatly depends on the characteristics of their images. After briefly discussing the required work-up, we analyze the most relevant imaging signs for assessing potential aggressiveness. We also describe the imaging aspects of the various types of lesion matrices and their clinical implications.


Assuntos
Doenças Ósseas , Doenças das Cartilagens , Humanos
11.
Radiology ; 308(3): e230193, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37698480

RESUMO

Background Initial imaging work-up using radiography and CT arthrography sometimes can be insufficient to identify a scapholunate (SL) instability (SLI) in patients suspected of having SL ligament tears. Purpose To determine the diagnostic performance of four-dimensional (4D) CT in the identification of SLI and apply the findings to patients suspected of having SLI and with inconclusive findings on radiographs and CT arthrograms. Materials and Methods This prospective single-center study enrolled participants suspected of having SLI (recent trauma, dorsal pain, positive Watson test results, decreased grip strength) between March 2015 and March 2020. Participants with wrist fractures, substantial joint stiffness, or history of wrist surgery were excluded. Each participant underwent radiography, CT arthrography, and 4D CT on the same day. Participants were divided into three groups: those with no SLI, those with SLI, and those with inconclusive results. SL gap and radioscaphoid and lunocapitate angle were measured using semiautomatic quantitative analysis of 4D CT images by two independent readers. Receiver operating characteristic curves were used to evaluate the diagnostic performance of 4D CT. Thresholds were determined with the Youden index and were applied to the inconclusive group. Results Of the 150 included participants (mean age, 41 years ± 14 [SD]; 102 male, 48 female), there were 63 with no SLI, 48 with SLI, and 39 with inconclusive results. The maximum value and range of SL gap measurements on 4D CT scans showed high sensitivity (83% [40 of 48] and 90% [43 of 48], respectively) and high specificity (95% [59 of 62] and 81% [50 of 62], respectively) in the identification of SLI. At least one of these parameters was abnormal on 4D CT scans in 17 of 39 (44%) participants in the inconclusive group, and 10 of 17 (59%) participants had confirmed SLI. In the 22 participants in the inconclusive group with no indication of SLI at 4D CT, follow-up showed no evidence of SLI in 10 (45%) and enabled confirmation of SLI via arthroscopy in three (14%). Conclusion Scapholunate gap measurements on kinematic 4D CT scans enabled correct identification of SLI in 59% of participants with inconclusive results on conventional images. ClinicalTrials.gov registration no. NCT02401568 © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Demehri and Ibad in this issue.


Assuntos
Tomografia Computadorizada Quadridimensional , Fraturas Ósseas , Humanos , Feminino , Masculino , Adulto , Estudos Prospectivos , Artroscopia , Ligamentos Articulares
12.
Forensic Sci Res ; 8(1): 30-40, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37415795

RESUMO

The distinction between falls and blows is a common and difficult task in forensic sciences. One of the most often used criteria to address this issue is the hat brim line (HBL) rule, which states that fall-related injuries do not lie above the HBL. Some studies, however, have found that the use of HBL rule is not so relevant. This study assesses the aetiologies, the number of fractures, and their location on the skull and the trunk in a sample of 400 individuals aged 20-49 years, which were CT scanned after traumas. This may facilitate the interpretation of such injuries in skeletonized or heavily decomposed bodies in which soft tissues are no longer available. Our aim is to improve the distinction rate between falls and blows by combining several criteria and assessing their predictability. Skeletal lesions were analysed using retrospective CT scans. Cases selected comprise 235 falls and 165 blows. We registered the presence and the number of fractures in 14 skeletal anatomical regions related to the two different aetiologies. We showed that the HBL rule should be used with caution, but there is nevertheless a possibility of discussing the aetiology of blunt fractures. Possibly, parameters like the anatomical location and the number of fractures by region can be used to distinguish falls and blows.

13.
Eur Radiol ; 33(12): 9262-9274, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37405504

RESUMO

OBJECTIVES: COVID-19 pandemic seems to be under control. However, despite the vaccines, 5 to 10% of the patients with mild disease develop moderate to critical forms with potential lethal evolution. In addition to assess lung infection spread, chest CT helps to detect complications. Developing a prediction model to identify at-risk patients of worsening from mild COVID-19 combining simple clinical and biological parameters with qualitative or quantitative data using CT would be relevant to organizing optimal patient management. METHODS: Four French hospitals were used for model training and internal validation. External validation was conducted in two independent hospitals. We used easy-to-obtain clinical (age, gender, smoking, symptoms' onset, cardiovascular comorbidities, diabetes, chronic respiratory diseases, immunosuppression) and biological parameters (lymphocytes, CRP) with qualitative or quantitative data (including radiomics) from the initial CT in mild COVID-19 patients. RESULTS: Qualitative CT scan with clinical and biological parameters can predict which patients with an initial mild presentation would develop a moderate to critical form of COVID-19, with a c-index of 0.70 (95% CI 0.63; 0.77). CT scan quantification improved the performance of the prediction up to 0.73 (95% CI 0.67; 0.79) and radiomics up to 0.77 (95% CI 0.71; 0.83). Results were similar in both validation cohorts, considering CT scans with or without injection. CONCLUSION: Adding CT scan quantification or radiomics to simple clinical and biological parameters can better predict which patients with an initial mild COVID-19 would worsen than qualitative analyses alone. This tool could help to the fair use of healthcare resources and to screen patients for potential new drugs to prevent a pejorative evolution of COVID-19. CLINICAL TRIAL REGISTRATION: NCT04481620. CLINICAL RELEVANCE STATEMENT: CT scan quantification or radiomics analysis is superior to qualitative analysis, when used with simple clinical and biological parameters, to determine which patients with an initial mild presentation of COVID-19 would worsen to a moderate to critical form. KEY POINTS: • Qualitative CT scan analyses with simple clinical and biological parameters can predict which patients with an initial mild COVID-19 and respiratory symptoms would worsen with a c-index of 0.70. • Adding CT scan quantification improves the performance of the clinical prediction model to an AUC of 0.73. • Radiomics analyses slightly improve the performance of the model to a c-index of 0.77.


Assuntos
COVID-19 , Humanos , SARS-CoV-2 , Pandemias , Modelos Estatísticos , Prognóstico , Estudos Retrospectivos
14.
Eur Radiol ; 33(9): 6322-6338, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37191922

RESUMO

OBJECTIVES: The purpose of this agreement was to establish evidence-based consensus statements on imaging of distal radioulnar joint (DRUJ) instability and triangular fibrocartilage complex (TFCC) injuries by an expert group using the Delphi technique. METHODS: Nineteen hand surgeons developed a preliminary list of questions on DRUJ instability and TFCC injuries. Radiologists created statements based on the literature and the authors' clinical experience. Questions and statements were revised during three iterative Delphi rounds. Delphi panelists consisted of twenty-seven musculoskeletal radiologists. The panelists scored their degree of agreement to each statement on an 11-item numeric scale. Scores of "0," "5," and "10" reflected complete disagreement, indeterminate agreement, and complete agreement, respectively. Group consensus was defined as a score of "8" or higher for 80% or more of the panelists. RESULTS: Three of fourteen statements achieved group consensus in the first Delphi round and ten statements achieved group consensus in the second Delphi round. The third and final Delphi round was limited to the one question that did not achieve group consensus in the previous rounds. CONCLUSIONS: Delphi-based agreements suggest that CT with static axial slices in neutral rotation, pronation, and supination is the most useful and accurate imaging technique for the work-up of DRUJ instability. MRI is the most valuable technique in the diagnosis of TFCC lesions. The main indication for MR arthrography and CT arthrography are Palmer 1B foveal lesions of the TFCC. CLINICAL RELEVANCE STATEMENT: MRI is the method of choice for assessing TFCC lesions, with higher accuracy for central than peripheral abnormalities. The main indication for MR arthrography is the evaluation of TFCC foveal insertion lesions and peripheral non-Palmer injuries. KEY POINTS: • Conventional radiography should be the initial imaging technique in the assessment of DRUJ instability. CT with static axial slices in neutral rotation, pronation, and supination is the most accurate method for evaluating DRUJ instability. • MRI is the most useful technique in diagnosing soft-tissue injuries causing DRUJ instability, especially TFCC lesions. • The main indications for MR arthrography and CT arthrography are foveal lesions of the TFCC.


Assuntos
Instabilidade Articular , Fibrocartilagem Triangular , Traumatismos do Punho , Humanos , Fibrocartilagem Triangular/diagnóstico por imagem , Traumatismos do Punho/diagnóstico por imagem , Imageamento por Ressonância Magnética , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/cirurgia , Artrografia , Articulação do Punho/diagnóstico por imagem , Artroscopia/métodos
15.
J Hand Surg Eur Vol ; 48(9): 895-902, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37211792

RESUMO

In this cadaveric study, we report quantitative dynamic four-dimensional CT evaluation of the effect on wrist kinematics of three intercarpal arthrodeses during radial and ulnar deviation. In five wrists, we successively performed scaphocapitate, four-corner and two-corner fusions. Four-dimensional CT examinations were performed prior to dissection and after each arthrodesis. The lunocapitate gap, posterior lunocapitate angle, radiolunate radial gap, radiolunate ulnar gap and radiolunate angle were assessed. After scaphocapitate arthrodesis, in radial deviation, we noted midcarpal diastasis and dorsal displacement of the capitate. In ulnar deviation, there was correction of that incongruence. After four-corner and two-corner fusions, in radial deviation, we noted radial radiolunate impingement and ulnar radiolunate incongruence. In ulnar deviation, after two-corner fusion, ulnar radiolunate impingement and radial radiolunate incongruence were present contrary to four-corner fusion. Our findings confirm that the constant radiocarpal and midcarpal congruence during radioulnar deviation in normal wrists is no longer possible with intercarpal kinematic modifications after these arthrodeses.

16.
Eur Radiol ; 33(9): 6381-6391, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37014406

RESUMO

OBJECTIVE: To compare the diagnostic performance of standard MRI and standard MRI + ZTE images for the detection of rotator cuff calcific tendinopathy (RCCT) and to describe the artifacts encountered with ZTE images, using computed radiography (CR) as a reference. METHODS: In a retrospective study, patients with suspicion of rotator cuff tendinopathy who underwent standard MRI + ZTE images after radiography were enrolled between June 2021 and June 2022. Images were independently analyzed for calcific deposit presence and ZTE images artifacts, by two radiologists. Diagnostic performance was calculated individually with MRI + CR as the reference standard. RESULTS: A total of 46 RCCT subjects (27 women; mean age, 55.3 years ± 12.4) and 51 control subjects (27 men; mean age, 45.5 ± 12.9) were evaluated. For both readers, there was an increase in the sensitivity for the identification of calcific deposits of MRI + ZTE compared to MRI (77% (95% CI: 64.5-86.8) and 75.4% (95% CI: 62.7-85.5) versus 57.4% (95% IC: 44.1-70) and 47.5% (95% IC: 34.6-60.7), for R1 and R2, respectively). Specificity was quite similar for both readers and both imaging techniques and ranged from 96.6% (95% IC: 93.3-98.5) to 98.7% (95% IC: 96.3-99.7). Hyperintense joint fluid (62.8% of patients), long head of the biceps tendon (in 60.8%), and subacromial bursa (in 27.8%) on ZTE were considered artifactual. CONCLUSION: The addition of ZTE images to a standard MRI protocol improved MRI diagnostic performance of RCCT, but with a suboptimal detection rate and a relatively high frequency of artifactual soft tissue signal hyperintensity. KEY POINTS: • Adding ZTE images to standard shoulder MRI improves the MR-based detection of rotator cuff calcific tendinopathy, but half of the calcification unseen with standard MRI remained unseen with ZTE MRI. On ZTE images, joint fluid and long head biceps tendon were hyperintense in about 60% of the shoulders, as well as the subacromial bursa in about 30%, without calcific deposit on conventional radiographs. • The detection rate of calcific deposits using ZTE images was dependent on the disease phase. In the calcific stage, it reached 100% in this study but remained at a maximum of 80.7% in the resorptive phase.


Assuntos
Manguito Rotador , Tendinopatia , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Adulto , Manguito Rotador/diagnóstico por imagem , Ombro , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Radiografia , Tendinopatia/diagnóstico por imagem
17.
J Hand Surg Am ; 48(5): 509.e1-509.e8, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-35016786

RESUMO

PURPOSE: The aim of this study was to test the validity and reliability of the assessments of scapholunate (SL) instability status on 4-dimensional (4D) computed tomography (CT) using wrist arthroscopy as a reference standard. METHODS: Thirty-three patients (16 men, 17 women; mean age, 48 ± 13 years) with suspected SL instability were evaluated prospectively with 4D-CT and wrist arthroscopy. Based on the arthroscopic testing of SL joint, 2 groups were defined: group 1 (n = 8) consisted of patients who had no, or slight, SL malalignment in the midcarpal space and group 2 (n = 25) consisted of patients who had moderate or severe SL malalignment. Two independent readers, who did not know the arthroscopic findings, used 4D-CT to evaluate the SL gap, lunocapitate angle (LCA), and radioscaphoid angle (mean and range values) during radioulnar deviation. RESULTS: The interobserver reliability was deemed good or excellent for most of the 4D-CT variables, except for the LCA range (moderate) and SL gap range (poor). For both readers, the SL gap mean, maximum, and minimum values were significantly higher (+67%, +78%, and +39%, respectively) and the LCA mean was significantly lower (-17%) in group 2 than in group 1. The radioscaphoid angle range values were lower (-34%) and the radioscaphoid angle mean values slightly higher (+4%) in group 2, but there was no significant difference between the 2 groups. The SL gap range values were also higher (+86% for R1 and +40% for R2) and the LCA range values also lower (-50% for R1 and -31% for R2) in group 2. CONCLUSIONS: Quantitative 4D-CT data corresponded well with the arthroscopic dynamic analysis of the SL joint in patients with suspected chronic SL instability. TYPE OF STUDY/LEVEL OF EVIDENCE: Diagnostic II.


Assuntos
Instabilidade Articular , Osso Semilunar , Osso Escafoide , Masculino , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/cirurgia , Osso Semilunar/diagnóstico por imagem , Osso Semilunar/cirurgia , Osso Escafoide/diagnóstico por imagem , Osso Escafoide/cirurgia , Ligamentos Articulares/cirurgia , Articulação do Punho/diagnóstico por imagem , Tomografia Computadorizada por Raios X
18.
Eur Radiol ; 33(1): 106-115, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35776181

RESUMO

OBJECTIVES: To study the relationship between opportunistic CT bone density measurements and the occurrence of new vertebral fractures after percutaneous vertebral cementoplasty (PVC) of osteoporotic vertebral compression fractures (OVCF). METHODS: A prospective analysis of retrospective data of 275 patients with OVCF treated by PVC between 2014 and 2019 with a clinico-radiological follow-up one year after treatment was conducted. Opportunistic bone density measurements were obtained at the trabecular bone of the L1 or an adjacent vertebra in Hounsfield units performed on the preoperative CT study. These density measurements values ​​were then compared between patients with and without new OCVF and in various population subgroups. RESULTS: There were 275 patients included, with 53 (19%) presenting a new OCVF and 24 (9%) developing a fracture cascade. The median opportunistic density measurements ​​in patients with recurrent OCVF were lower than those without (median 52[40.5]) HU and 77[49] HU)(p < 0.00001). Among the patients with new OVCF the median opportunistic density measurements in patients with fracture cascades were also lower than those without (44 HU and 62 HU, respectively) (p < 0.0096). Patients with density measurements under 61 HU were 3.6 times more likely to present recurrent fractures and those with density under 54 HU were 9.8 times more likely to develop a fracture cascade. The 36 HU threshold yielded a high specificity (90-91%) for the prediction of recurrent fractures and fracture cascade but with low sensitivity (respectively 26% and 37%). CONCLUSION: Low opportunistic vertebral density measurements are associated with a higher risk of OVCF and fracture cascades after PVC. KEY POINTS: • Low opportunistic density measurements are associated with a higher risk of OVCF and fracture cascades after PVC. • Measuring bone density before performing a PVC could help predict the risk of new vertebral fracture after treatment • Patient management could be adapted according to bone density.


Assuntos
Doenças Ósseas Metabólicas , Cementoplastia , Fraturas por Compressão , Fraturas por Osteoporose , Fraturas da Coluna Vertebral , Vertebroplastia , Humanos , Densidade Óssea , Estudos de Casos e Controles , Fraturas por Compressão/diagnóstico por imagem , Fraturas por Compressão/cirurgia , Vértebras Lombares/lesões , Fraturas por Osteoporose/diagnóstico por imagem , Fraturas por Osteoporose/cirurgia , Estudos Retrospectivos , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia
20.
Can Assoc Radiol J ; 74(2): 404-414, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36207066

RESUMO

Objectives: To ascertain the role of CT and conventional radiographs for the initial characterization of focal bone lesions.Methods: Images from 184 patients with confirmed bone tumors included in an ethics committee-approved study were retrospectively evaluated. The reference for benign-malignant distribution was based on histological analysis and long-term follow-up. Radiographs and CT features were analyzed by 2 independent musculoskeletal radiologists blinded to the final diagnosis. Lesion margins, periosteal reaction, cortical lysis, endosteal scalloping, presence of pathologic fracture, and lesion mineralization were evaluated. Results: The benign-malignant distribution in the study population was 68.5-31.5% (126 benign and 58 malignant). In the lesions that could be seen in both radiographs and CT, the performance of these methods for the benign-malignant differentiation was similar (accuracy varying from 72.8% to 76.5%). The interobserver agreement for the overall evaluation of lesion aggressiveness was considerably increased on CT compared to radiographs (Kappa of .63 vs .22). With conventional radiographs, 18 (9.7%) and 20 (10.8%) of the lesions evaluated were not seen respectively by readers 1 and 2. Among these unseen lesions, 50%-61.1% were located in the axial skeleton. Compared to radiographs, the number of lesions with cortical lysis and endosteal scalloping was 26-34% higher with CT. Conclusion: Although radiographs remain the primary imaging tool for lesions in the peripheral skeleton, CT should be performed for axial lesions. CT imaging can assess the extent of perilesional bone lysis more precisely than radiographs with a better evaluation of lesion fracture risk.


Assuntos
Neoplasias Ósseas , Tomografia Computadorizada por Raios X , Humanos , Estudos Retrospectivos , Variações Dependentes do Observador , Tomografia Computadorizada por Raios X/métodos , Neoplasias Ósseas/diagnóstico por imagem , Radiografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...